Fire Resistance Ratings: ibc table 601

type VA floor to type VB structural frame

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly category: ibc table 6015 rowsPage 3 of 3
assembly categoryrecord idassembly descriptionassembly typeconstruction materialconstruction type IBCfire rating hr (hr)key materials
ibc table 601type VA floorType VA Floor Constructionfloor assemblyprotected combustibleVA1protected wood joist
ibc table 601type VA structural frameType VA Primary Structural Framestructural framecombustible protectedVA1protected wood frame
ibc table 601type VB bearing wall extType VB Exterior Bearing Wallbearing wall exteriorcombustible unprotectedVB0unprotected wood frame
ibc table 601type VB floorType VB Floor Constructionfloor assemblyunprotected combustibleVB0wood unprotected
ibc table 601type VB structural frameType VB Primary Structural Framestructural framecombustible unprotectedVB0unprotected wood frame