Fire Resistance Ratings: wall_cmu

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly_category: wall_cmu3 rows
assembly categoryrecord idassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materialsmin thickness in (in)notes
wall_cmucmu_carbonate_1hrCMU Wall — Carbonate Aggregate — 1 Hourwallconcrete_masonry_unit1CMU_carbonate_aggregate, siliceous_aggregate_gives_higher_thicknesses3.2Equivalent thickness = solid thickness in hollow unit; per IBC Table 722.5.1.2 and ACI 216.1; CMU aggregate type governs thickness requirement
wall_cmucmu_carbonate_2hrCMU Wall — Carbonate Aggregate — 2 Hourwallconcrete_masonry_unit2CMU_carbonate_aggregate4.6Carbonate: limestone or dolomite coarse aggregate
wall_cmucmu_carbonate_3hrCMU Wall — Carbonate Aggregate — 3 Hourwallconcrete_masonry_unit3CMU_carbonate_aggregate6.210-inch CMU typically satisfies 3-hour with carbonate aggregate