Fire Resistance Ratings: wall_gypsum_wood_stud

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly_category: wall_gypsum_wood_stud2 rows
assembly categoryrecord idSTC rating (dimensionless)UL design numberassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materialsmin thickness in (in)notesweight psf (lb/ft2)
wall_gypsum_wood_studgwb_wood_1layer_1hr35W411Gypsum Board on Wood Studs — 1 Layer Each Side — 1 Hourwallgypsum_wood_stud15/8-in_type_X_gypsum_board, 2x4_wood_studs_16-in_oc5.51 layer 5/8-in Type X GWB each side on 2x4 wood studs 16-in o.c.; UL W41110
wall_gypsum_wood_studgwb_wood_2layer_2hr54W412Gypsum Board on Wood Studs — 2 Layer Each Side — 2 Hourwallgypsum_wood_stud25/8-in_type_X_gypsum_board_2_layers_each_side, 2x4_wood_studs72 layers 5/8-in Type X GWB each side on 2x4 studs 16-in o.c.; UL W41214