Fire Resistance Ratings: wall_concrete

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly_category: wall_concrete3 rows
assembly categoryrecord idassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materialsmin thickness in (in)notes
wall_concreteconcrete_carbonate_2hrCast-in-Place Concrete Wall — Carbonate Aggregate — 2 Hourwallcast_in_place_concrete2normalweight_concrete_carbonate4.6Carbonate aggregate (limestone) provides better fire resistance than siliceous
wall_concreteconcrete_lw_2hrCast-in-Place Concrete Wall — Lightweight — 2 Hourwallcast_in_place_concrete2lightweight_concrete3.5Sand-lightweight concrete; 105-120 pcf density
wall_concreteconcrete_siliceous_1hrCast-in-Place Concrete Wall — Siliceous Aggregate — 1 Hourwallcast_in_place_concrete1normalweight_concrete_siliceous3.5Solid concrete wall; siliceous aggregate (granite/quartz); minimum per ACI 216.1-14 Table 4.4.2

This is a sample. Search the full fire resistance ratings dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE