Fire Resistance Ratings: wall_gypsum_steel_stud

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly_category: wall_gypsum_steel_stud3 rows
assembly categoryrecord idSTC rating (dimensionless)UL design numberassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materialsmin thickness in (in)notesweight psf (lb/ft2)
wall_gypsum_steel_studgwb_steel_1layer_1hr45U411Gypsum Board on Steel Studs — 1 Layer Each Side — 1 Hourwallgypsum_steel_stud15/8-in_type_X_gypsum_board, 3-5/8-in_25-gauge_steel_studs3.6251 layer 5/8-in Type X GWB each side; 3-5/8-in steel studs 16-in o.c.; per UL Design U4118
wall_gypsum_steel_studgwb_steel_2layer_2hr54U419Gypsum Board on Steel Studs — 2 Layer Each Side — 2 Hourwallgypsum_steel_stud25/8-in_type_X_gypsum_board_2_layers_each_side, 3-5/8-in_steel_studs5.52 layers 5/8-in Type X GWB each side; 3-5/8-in steel studs 24-in o.c.; per UL Design U41915
wall_gypsum_steel_studgwb_steel_double_stud_2hr59U305Double Steel Stud Wall with 2 Layers GWB — 2 Hourwallgypsum_steel_stud_double25/8-in_type_X_gypsum_board_2_layers_each_face, double_3-5/8-in_steel_studs_with_gap9Double stud rows separated 1-in; 2 layers 5/8-in Type X each face; per UL U30518

This is a sample. Search the full fire resistance ratings dataset and 300+ more by creating a free account and accessing the database.