Fire Resistance Ratings: beam_sfrm

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly_category: beam_sfrm2 rows
assembly categoryrecord idassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materials
beam_sfrmbeam_sfrm_1.5hrSteel Beam SFRM Protection — 1.5 Hourbeamstructural_steel_with_sfrm1.5W-shape_steel_beam, spray_applied_SFRM
beam_sfrmbeam_sfrm_2hrSteel Beam SFRM Protection — 2 Hourbeamstructural_steel_with_sfrm2W-shape_steel_beam, spray_applied_SFRM

This is a sample. Search the full fire resistance ratings dataset and 300+ more by creating a free account and accessing the database.