Fire Resistance Ratings: ibc table 601

type IIB floor to type VA bearing wall ext

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly category: ibc table 60110 rowsPage 2 of 3
assembly categoryrecord idassembly descriptionassembly typeconstruction materialconstruction type IBCfire rating hr (hr)key materials
ibc table 601type IIB floorType IIB Floor Constructionfloor assemblyunprotected noncombustibleIIB0noncombustible unprotected
ibc table 601type IIB structural frameType IIB Primary Structural Framestructural frameunprotected noncombustibleIIB0noncombustible unprotected
ibc table 601type IIIA bearing wall extType IIIA Exterior Bearing Wallbearing wall exteriormasonry or concreteIIIA2brick masonry or concrete
ibc table 601type IIIA floorType IIIA Floor Constructionfloor assemblywood or protected steelIIIA1wood or protected members
ibc table 601type IIIA structural frameType IIIA Primary Structural Framestructural frameprotected noncombustible with combustible interiorIIIA1protected noncombustible frame
ibc table 601type IIIB bearing wall extType IIIB Exterior Bearing Wallbearing wall exteriormasonry or concreteIIIB2brick masonry or concrete
ibc table 601type IIIB floorType IIIB Floor Constructionfloor assemblycombustible unprotectedIIIB0wood unprotected
ibc table 601type IIIB structural frameType IIIB Primary Structural Framestructural framenoncombustible exterior combustible interiorIIIB0noncombustible exterior unprotected
ibc table 601type IV HT structural frameType IV Heavy Timber Structural Framestructural frameheavy timberIV HT0heavy timber min 8x8 columns
ibc table 601type VA bearing wall extType VA Exterior Bearing Wallbearing wall exteriorcombustible protectedVA1protected wood frame

What else is in Engineering Database