Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Fire Resistance Ratings: wall cmu

cmu siliceous 3hr to cmu siliceous 4hr

Fire resistance ratings for building assemblies per UL/ASTM E119 — IBC Table 601 construction-type requirements (Types IA through VB), CMU wall equivalent-thickness ratings by aggregate type, gypsum board on steel/wood stud assemblies, concrete slab and wall thicknesses, composite steel deck/concrete floors, spray-applied fireproofing (SFRM) for columns and beams by W/D ratio, concrete-encased column ratings, and fire door assembly ratings (20-minute through 3-hour). Sources: IBC 2021 Table 601, ACI 216.1-14, UL Fire Resistance Directory, GA-600-2021, NFPA 80-2022, ASTM E119.

Civil Engineeringassembly category: wall cmu2 rowsPage 2 of 2
assembly categoryrecord idassembly descriptionassembly typeconstruction materialfire rating hr (hr)key materialsmin thickness in (in)
wall cmucmu siliceous 3hrCMU Wall — Siliceous Aggregate — 3 Hourwallconcrete masonry unit3CMU siliceous aggregate6.9
wall cmucmu siliceous 4hrCMU Wall — Siliceous Aggregate — 4 Hourwallconcrete masonry unit4CMU siliceous aggregate8.8