Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation type: functional2 rowsPage 2 of 2
insulation typerecord idaltitude correction factorapplication noteclearance mm (mm)creepage mm (mm)material groupovervoltage categorypollution degreestandardworking voltage V (V)
functionalfunc pd3 ovc1 501Functional insulation; PD3 (industrial); OVC I; material group I0.81.5II3IEC60664-150
functionalfunc pd3 ovc1 6001Functional insulation; PD3; OVC I; 600V0.86.3II3IEC60664-1600