Clearance Creepage: ipc_pcb

Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation_type: ipc_pcb3 rows
insulation typerecord idapplication noteclearance mm (mm)standardworking voltage V (V)
ipc_pcbpcb_ext_coated_0_15VB4 polymer-coated external; 0-15V; conformal coat reduces distance"0.05IPC-2221B7.5
ipc_pcbpcb_ext_coated_101_150VB4 polymer-coated external; 101-150V"0.4IPC-2221B125
ipc_pcbpcb_ext_coated_251_300VB4 polymer-coated external; 251-300V"0.4IPC-2221B275

This is a sample. Search the full clearance creepage dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE