Clearance Creepage: supplementary

Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation_type: supplementary3 rows
insulation typerecord idaltitude correction factorapplication noteclearance mm (mm)creepage mm (mm)material groupovervoltage categorypollution degreestandardworking voltage V (V)
supplementarysupp_pd2_ovc2_1501Supplementary insulation; PD2; OVC II; 150V0.50.8III2IEC60664-1150
supplementarysupp_pd2_ovc2_2501Supplementary insulation; PD2; OVC II; 250V11.25III2IEC60664-1250
supplementarysupp_pd2_ovc2_501Supplementary insulation; same distances as basic for same pollution/OVC; combined with basic to form double insulation0.20.6III2IEC60664-150

This is a sample. Search the full clearance creepage dataset and 300+ more by creating a free account and accessing the database.