Clearance Creepage: double

Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation_type: double2 rows
insulation typerecord idaltitude correction factorapplication noteclearance mm (mm)creepage mm (mm)material groupovervoltage categorypollution degreestandardworking voltage V (V)
doubledouble_pd2_ovc2_2501Double insulation (basic+supplementary combined); same min distances as reinforced for same conditions1.52.5III2IEC60664-1250
doubledouble_pd2_ovc2_6001Double insulation; PD2; OVC II; 600V; basic + supplementary path must each meet basic requirements5.56.4III2IEC60664-1600