Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation_type: basic3 rows
insulation typerecord idaltitude correction factorapplication noteclearance mm (mm)creepage mm (mm)material groupovervoltage categorypollution degreestandardworking voltage V (V)
basicbasic_pd1_ovc1_1501Basic insulation; PD1; OVC I; 150V0.150.6anyI1IEC60664-1150
basicbasic_pd1_ovc1_3001Basic insulation; PD1; OVC I; 300V0.30.8anyI1IEC60664-1300
basicbasic_pd1_ovc1_501Basic insulation; PD1; OVC I (consumer electronics connected to protected source)0.080.4anyI1IEC60664-150

This is a sample. Search the full clearance creepage dataset and 300+ more by creating a free account and accessing the database.