Clearance Creepage: reinforced

Minimum electrical clearance and creepage distances per IEC 60664-1:2020 (insulation coordination for low-voltage equipment up to 1000V AC / 1500V DC) and IPC-2221B (PCB conductor spacing). Indexed by insulation type (functional, basic, supplementary, reinforced, double, ipc_pcb), pollution degree (1–3), overvoltage category (I–IV), and working voltage (V). Clearance is shortest air-path distance; creepage is shortest surface-path distance. Critical for PCB layout, enclosure design, and product safety compliance (CE, UL, CSA).

Electrical Engineeringinsulation_type: reinforced3 rows
insulation typerecord idaltitude correction factorapplication noteclearance mm (mm)creepage mm (mm)material groupovervoltage categorypollution degreestandardworking voltage V (V)
reinforcedreinf_pd1_ovc1_1501Reinforced insulation; PD1; OVC I; 150V; reinforced = basic one impulse level up0.31.2anyI1IEC60664-1150
reinforcedreinf_pd1_ovc1_3001Reinforced insulation; PD1; OVC I; 300V0.61.6anyI1IEC60664-1300
reinforcedreinf_pd1_ovc1_501Reinforced insulation; PD1; OVC I; = 2× basic clearance per IEC 60664-1 Table F.2 next impulse step; used for double-insulated Class II products0.160.8anyI1IEC60664-150

This is a sample. Search the full clearance creepage dataset and 300+ more by creating a free account and accessing the database.