Welding Preheat Interpass: quenched_tempered

Minimum preheat and maximum interpass temperatures for welding per AWS D1.1, ASME BPVC, ASME B31.3, and EN 1011. Covers carbon steels (AWS categories A/B), HSLA (category C, HPS 70W/100W), quenched and tempered (category D), Cr-Mo alloys (P5/P11/P22/P91/P4/P5B), austenitic stainless (P8), duplex stainless (P10H), nickel alloys, aluminum, titanium, and copper. Each record includes base metal group, thickness range, carbon equivalent, preheat/interpass temperatures in both F and C, PWHT requirements, hydrogen control level, and welding process notes. 46 records.

Civil Engineeringbase_metal_group: quenched_tempered3 rows
base metal groupAWS group numberPWHT requiredbase metal examplescarbon equivalent CE maxhydrogen controlinterpass max C (degC)interpass max F (degF)preheat min C (degC)preheat min F (degF)record keythickness range inthickness range mmwelding process notes
quenched_temperedDnoA514 / A517 (all grades T1 A-F), A709 HPS100W, A7100.5low_H2_required20540079175D#1-1/2_to_2-1/21-1/2_to_2-1/238_to_64Q&T steels: max interpass 400°F strictly enforced; use E11018 or matching filler; no interpass calc basis — max preheat = interpass max
quenched_temperedDnoA514 / A517 (all grades T1 A-F), A709 HPS100W, A7100.5low_H2_required20540052125D#3/4_to_1-1/23/4_to_1-1/219_to_38Q&T steels: max interpass 400°F strictly enforced; use E11018 or matching filler; no interpass calc basis — max preheat = interpass max
quenched_temperedDnoA514 / A517 (all grades T1 A-F), A709 HPS100W, A7100.5low_H2_required205400107225D#over_2-1/2over_2-1/2over_64Q&T steels: max interpass 400°F strictly enforced; use E11018 or matching filler; no interpass calc basis — max preheat = interpass max

This is a sample. Search the full welding preheat interpass dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE