Minimum preheat and maximum interpass temperatures for welding per AWS D1.1, ASME BPVC, ASME B31.3, and EN 1011. Covers carbon steels (AWS categories A/B), HSLA (category C, HPS 70W/100W), quenched and tempered (category D), Cr-Mo alloys (P5/P11/P22/P91/P4/P5B), austenitic stainless (P8), duplex stainless (P10H), nickel alloys, aluminum, titanium, and copper. Each record includes base metal group, thickness range, carbon equivalent, preheat/interpass temperatures in both F and C, PWHT requirements, hydrogen control level, and welding process notes. 46 records.

Civil Engineeringbase_metal_group: duplex_SS1 row
base metal groupAWS group numberPWHT requiredbase metal exampleshydrogen controlinterpass max C (degC)interpass max F (degF)preheat min C (degC)preheat min F (degF)record keythickness range inthickness range mmwelding process notes
duplex_SSP10HnoASTM A790 2205 / A928 2205; 22Cr-5Ni-3Mo (S31803 / S32205)low_H2_required1503001050P10H#anyanyanyPreheat to remove chill (50°F min); critical max interpass 300°F to maintain ferrite/austenite balance (30-50%); use matching ER2209 filler; avoid over-heating