Welding Preheat Interpass: HSLA

Minimum preheat and maximum interpass temperatures for welding per AWS D1.1, ASME BPVC, ASME B31.3, and EN 1011. Covers carbon steels (AWS categories A/B), HSLA (category C, HPS 70W/100W), quenched and tempered (category D), Cr-Mo alloys (P5/P11/P22/P91/P4/P5B), austenitic stainless (P8), duplex stainless (P10H), nickel alloys, aluminum, titanium, and copper. Each record includes base metal group, thickness range, carbon equivalent, preheat/interpass temperatures in both F and C, PWHT requirements, hydrogen control level, and welding process notes. 46 records.

Civil Engineeringbase_metal_group: HSLA3 rows
base metal groupAWS group numberPWHT requiredbase metal examplescarbon equivalent CE maxhydrogen controlinterpass max C (degC)interpass max F (degF)preheat min C (degC)preheat min F (degF)record keythickness range inthickness range mmwelding process notes
HSLACnoA572 Gr60/Gr65, A537 Cl1/Cl2, A709 Gr50/50W, A8520.45low_H2_required205400107225C#1-1/2_to_2-1/21-1/2_to_2-1/238_to_64Low-hydrogen processes mandatory; A852 max interpass 400°F per AWS D1.1 note
HSLACnoA572 Gr60/Gr65, A537 Cl1/Cl2, A709 Gr50/50W, A8520.45low_H2_required20540066150C#3/4_to_1-1/23/4_to_1-1/219_to_38Low-hydrogen processes mandatory; A852 max interpass 400°F per AWS D1.1 note
HSLACnoA572 Gr60/Gr65, A537 Cl1/Cl2, A709 Gr50/50W, A8520.45low_H2_required205400150300C#over_2-1/2over_2-1/2over_64Low-hydrogen processes mandatory; A852 max interpass 400°F per AWS D1.1 note