Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Retaining Wall Design: SEGMENTAL BLOCK MSE

Typical design parameters for common retaining wall types — height ranges, base width ratios, embedment depth, stability factors of safety, backfill and drainage requirements

Civil Engineeringwall type: SEGMENTAL BLOCK MSE1 row
wall typebackfill requirementbase width to height ratio max (dimensionless)base width to height ratio min (dimensionless)drainage requirementglobal stability fos min (dimensionless)height max ft (ft)height min ft (ft)min embedment depth ft (ft)overturning fos min (dimensionless)reinforcement notessliding fos min (dimensionless)typical applications
SEGMENTAL BLOCK MSECompacted granular fill; max 35% passing #200; phi>=28 deg0.70.6Drainage aggregate directly behind facing; collector pipe at base1.520302Geogrid reinforcement at specified vertical intervals; connection strength check required1.5Commercial and residential; landscape walls; low-cost highway applications

What else is in Engineering Database

Calculators that use this data

Related data