Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Retaining Wall Design: CRIB WALL

Typical design parameters for common retaining wall types — height ranges, base width ratios, embedment depth, stability factors of safety, backfill and drainage requirements

Civil Engineeringwall type: CRIB WALL1 row
wall typebackfill requirementbase width to height ratio max (dimensionless)base width to height ratio min (dimensionless)drainage requirementglobal stability fos min (dimensionless)height max ft (ft)height min ft (ft)min embedment depth ft (ft)overturning fos min (dimensionless)reinforcement notessliding fos min (dimensionless)typical applications
CRIB WALLGranular free-draining backfill; compacted in lifts within cribs0.80.5Internal drainage through crib openings; no separate system required1.520502Interlocking precast concrete or timber headers and stretchers; no active reinforcement1.5Low- to medium-height walls; natural aesthetic; stream corridors; older highway walls