Measurement Uncertainty: pressure_transducer

GUM-compliant measurement uncertainty budget components and coverage factors for common engineering measurements. Covers Type A (statistical) and Type B (non-statistical) uncertainty sources with standard uncertainties, expanded uncertainties at k=2 (95%), and confidence levels for: length/dimension (caliper, micrometer, CMM, gauge block), mass (analytical balance, platform scale), temperature (Type K thermocouple, Pt100 RTD, IR pyrometer), pressure (Bourdon gauge, electronic transducer, liquid manometer), flow (orifice plate, turbine meter, Coriolis, ultrasonic transit-time), electrical (DMM, power analyzer), force (load cell), and torque (torque wrench). Also includes coverage factor reference rows (k=1/2/3, 68/95/99.7%) and distribution divisors (rectangular, triangular, normal, U-shaped). Per ISO/IEC Guide 98-3:2008 (GUM), NIST TN 1297, ISO/IEC 17025:2017.

General Referencemeasurement_type: pressure_transducer3 rows
measurement typeuncertainty sourceconfidence level pct (%)coverage factor kdistributiondivisorexpanded uncertainty k2expanded uncertainty unitnotesstandard uncertainty unitstandard uncertainty valueuncertainty type
pressure_transducercalibration952normal20.2pct_FSElectronic pressure transducer calibration; typical accuracy class 0.1-0.25% FS; NIST-traceable deadweight tester calibration; U95 = 0.20% FSpct_FS0.1Type_B
pressure_transducercombined_standard_uncertainty952normal10.24pct_FSRSS: sqrt(0.10^2+0.03^2+0.05^2+0.05^2) = 0.123% FS; U95 = 0.25% FS; electronic transducer significantly better than Bourdon gaugepct_FS0.12Combined
pressure_transducerrepeatability952normal10.1pct_FSType A: 10 repeat measurements at constant pressure; electronic transducer sd typically 0.03-0.07% FSpct_FS0.05Type_A