Measurement Uncertainty: flow_coriolis_meter
GUM-compliant measurement uncertainty budget components and coverage factors for common engineering measurements. Covers Type A (statistical) and Type B (non-statistical) uncertainty sources with standard uncertainties, expanded uncertainties at k=2 (95%), and confidence levels for: length/dimension (caliper, micrometer, CMM, gauge block), mass (analytical balance, platform scale), temperature (Type K thermocouple, Pt100 RTD, IR pyrometer), pressure (Bourdon gauge, electronic transducer, liquid manometer), flow (orifice plate, turbine meter, Coriolis, ultrasonic transit-time), electrical (DMM, power analyzer), force (load cell), and torque (torque wrench). Also includes coverage factor reference rows (k=1/2/3, 68/95/99.7%) and distribution divisors (rectangular, triangular, normal, U-shaped). Per ISO/IEC Guide 98-3:2008 (GUM), NIST TN 1297, ISO/IEC 17025:2017.
| measurement type | uncertainty source | confidence level pct (%) | coverage factor k | distribution | divisor | expanded uncertainty k2 | expanded uncertainty unit | notes | standard uncertainty unit | standard uncertainty value | uncertainty type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| flow_coriolis_meter | calibration | 95 | 2 | normal | 2 | 0.2 | pct_flow | Factory calibration traceable to NIST; Coriolis accuracy class typically 0.1-0.2% of reading; expanded U95 = 0.20% | pct_flow | 0.1 | Type_B |
| flow_coriolis_meter | combined_standard_uncertainty | 95 | 2 | normal | 1 | 0.24 | pct_flow | RSS: sqrt(0.05^2+0.10^2+0.03^2) = 0.116% flow; U95 = 0.23% flow; Coriolis is reference-class flow measurement | pct_flow | 0.12 | Combined |
| flow_coriolis_meter | repeatability | 95 | 2 | normal | 1 | 0.06 | pct_flow | Excellent repeatability: sd typically 0.02-0.05% for stable flow; one of best available flow technologies | pct_flow | 0.03 | Type_A |