Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Equipment Failure Rates: Sending Unit

C13-100 to C13-300

Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.

Electrical Engineeringequipment type: Sending Unit3 rows
equipment typeclass codedescriptionfailure rate per year (failures/year)failures (count)mdt hours (h)mtbf hours (h)mttm hours (h)mttr hours (h)standardsurveyunit years (unit-years)
Sending UnitC13-100Sending unit, air velocity0.006273471.31,396,4200.046.96IEEE Std 3006.8-2018 Table 2USACE PREP7,492.2
Sending UnitC13-200Sending unit, pressure0.012556952.22697,6540.15.82IEEE Std 3006.8-2018 Table 2USACE PREP7,565.9
Sending UnitC13-300Sending unit, temperature0.001005290.398,716,4960.25IEEE Std 3006.8-2018 Table 2USACE PREP28,856