Equipment Failure Rates: Air_Separator
Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.
| equipment type | class code | description | failure rate per year (failures/year) | failures (count) | mdt hours (h) | mtbf hours (h) | mttm hours (h) | mttr hours (h) | standard | survey | unit years (unit-years) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Air_Separator | H06-000 | Air separator, all types | 0.106273 | 9 | 3.35 | 82,429 | 0.88 | 6.31 | IEEE Std 3006.8-2018 Table 2 | USACE_PREP | 84.7 |