Equipment Failure Rates: Pump

Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.

Electrical Engineeringequipment_type: Pump3 rows
equipment typeclass codedescriptionfailure rate per year (failures/year)failures (count)mdt hours (h)mtbf hours (h)mttm hours (h)mttr hours (h)standardsurveyunit years (unit-years)
PumpH26-110Pump, centrifugal, with drive0.1215922,6557.9572,0452.2111.95IEEE Std 3006.8-2018 Table 2USACE_PREP21,835.4
PumpH26-120Pump, centrifugal, w/o drive0.1276212621.5268,6411.0411.28IEEE Std 3006.8-2018 Table 2USACE_PREP2,052.9
PumpH26-200Pump, positive displacement0.120141804.7472,9150.77.91IEEE Std 3006.8-2018 Table 2USACE_PREP1,498.2