Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Equipment Failure Rates: Pipe

H25-111 to H25-450A

Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.

Electrical Engineeringequipment type: Pipe10 rows
equipment typeclass codedescriptionfailure rate per year (failures/year)failures (count)mdt hours (h)mtbf hours (h)mttm hours (h)mttr hours (h)standardsurveyunit years (unit-years)
PipeH25-111Pipe, flex, reinforced, <0.01095838799,4408IEEE Std 3006.8-2018 Table 2USACE PREP273.8
PipeH25-112Pipe, flex, non-reinforced, >0.01454433.6602,29043.33IEEE Std 3006.8-2018 Table 2USACE PREP206.3
PipeH25-122Pipe, flex, reinforced, >0.00298842.252,931,8482.25IEEE Std 3006.8-2018 Table 2USACE PREP1,338.7
PipeH25-310Pipe, refrigerant, < 25 mm per0.00037932.1123,107,704210.67IEEE Std 3006.8-2018 Table 2USACE PREP7,913.6
PipeH25-320Pipe, refrigerant, 25 mm to 800.00090738.739,657,5208.788IEEE Std 3006.8-2018 Table 2USACE PREP3,307.4
PipeH25-410APipe, water, ≤ 50 mm per 30.50.00149907,943,294IEEE Std 3006.8-2018 Table 2USACE PREP462.5
PipeH25-420Pipe, water, 50 mm to 100 mm0.02053614.08426,69214.08IEEE Std 3006.8-2018 Table 2USACE PREP292.3
PipeH25-430APipe, water, 100 mm to 2000.0025804,614,729IEEE Std 3006.8-2018 Table 2USACE PREP268.7
PipeH25-440APipe, water, 200 mm to 3000.000850814,008,6128IEEE Std 3006.8-2018 Table 2USACE PREP815.6
PipeH25-450APipe, water, > 300 mm per 30.50.0849840140,094IEEE Std 3006.8-2018 Table 2USACE PREP8.2