Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Equipment Failure Rates: Heat Exchanger

H21-100 to H21-400

Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.

Electrical Engineeringequipment type: Heat Exchanger4 rows
equipment typeclass codedescriptionfailure rate per year (failures/year)failures (count)mdt hours (h)mtbf hours (h)mttm hours (h)mttr hours (h)standardsurveyunit years (unit-years)
Heat ExchangerH21-100Heat exchanger, boiler system,0.17012916419.1551,49018.157.22IEEE Std 3006.8-2018 Table 2USACE PREP964
Heat ExchangerH21-200Heat exchanger, lube oil0.0274621514.46318,9826.5212.21IEEE Std 3006.8-2018 Table 2USACE PREP546.2
Heat ExchangerH21-310Heat exchanger, radiator, small0.036077650.6242,8170.2312.55IEEE Std 3006.8-2018 Table 2USACE PREP1,801.7
Heat ExchangerH21-400Heat exchanger, water to water0.018104280.86483,8630.3810.1IEEE Std 3006.8-2018 Table 2USACE PREP1,546.6