Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Equipment Failure Rates: Condensers

H12-100 to H12-200

Equipment failure rates, MTBF, MTTR, and downtime statistics for electrical and mechanical plant equipment. Primary data from the USACE PREP reliability database (IEEE Std 3006.8-2018 Table 2), covering ~280 equipment classes. Supplemental data from IEEE motor and transformer surveys.

Electrical Engineeringequipment type: Condensers2 rows
equipment typeclass codedescriptionfailure rate per year (failures/year)failures (count)mdt hours (h)mtbf hours (h)mttm hours (h)mttr hours (h)standardsurveyunit years (unit-years)
CondensersH12-100Condensers, double tube0.02678282.63327,0872.632.5IEEE Std 3006.8-2018 Table 2USACE PREP298.7
CondensersH12-200Condensers, propeller type fans with coils, direct expansion (DX)0.127312674.9168,8091.988.18IEEE Std 3006.8-2018 Table 2USACE PREP2,097.2