Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Attached Growth Design: trickling filter

tf effluent bod nit to tf germain k refinery

Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess type: trickling filter10 rowsPage 4 of 8
process typeparameter idparameter nameunitvalue maxvalue min
trickling filtertf effluent bod nitEffluent BOD - BOD removal and nitrificationmg/L20
trickling filtertf effluent nh4 low rateEffluent NH4-N - low ratemg/L5
trickling filtertf effluent nh4 nitEffluent NH4-N - BOD removal and nitrificationmg/L3
trickling filtertf germain k domesticGermain k value - domestic wastewaterdimensionless (L/s)^0.5/m²0.21
trickling filtertf germain k fruit canningGermain k value - fruit canningdimensionless (L/s)^0.5/m²0.181
trickling filtertf germain k kraft millGermain k value - kraft milldimensionless (L/s)^0.5/m²0.108
trickling filtertf germain k meat packingGermain k value - meat packingdimensionless (L/s)^0.5/m²0.216
trickling filtertf germain k pharmaceuticalGermain k value - pharmaceuticaldimensionless (L/s)^0.5/m²0.221
trickling filtertf germain k potato processingGermain k value - potato processingdimensionless (L/s)^0.5/m²0.351
trickling filtertf germain k refineryGermain k value - refinerydimensionless (L/s)^0.5/m²0.059