Attached Growth Design: ifas

Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess_type: ifas3 rows
process typeparameter idparameter nameunitvalue maxvalue min
ifasifas_fixed_rope_applied_surfaceFixed rope or web applied specific surface aream²/m³ tank volume10050
ifasifas_fixed_rope_fill_fractionFixed rope or web media fill fraction%8070
ifasifas_fixed_rope_hrtFixed rope or web aerobic HRTh5