Attached Growth Design: mbbr

Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess_type: mbbr3 rows
process typeparameter iddescriptionparameter name
mbbrmbbr_config_bardenphoMBBR Bardenpho system for biological nitrogen removal with preanoxic and postanoxic reactors. External carbon must be added to postanoxic reactor. Chemical addition may be used for effluent P removal (total nitrogen <3 mg/L).MBBR configuration - Bardenpho nitrogen removal
mbbrmbbr_config_bod_nitMBBR system for BOD removal and nitrification. Most BOD removal occurs in first stage before subsequent single or multiple stage reactors for nitrification.MBBR configuration - BOD removal and nitrification
mbbrmbbr_config_bod_removal_chem_precipMBBR system for BOD removal and phosphorus removal by chemical precipitation. Aerobic tank may be single or two-stage design.MBBR configuration - BOD removal with chemical precipitation

This is a sample. Search the full attached growth design dataset and 350+ more by creating a free account and accessing the database.

Get started for FREE