Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess_type: tfas3 rows
process typeparameter idparameter nameunitvalue maxvalue minvalue typical
tfastfas_bod_loadingTrickling filter BOD loading - TFASkg BOD/m³·d41.62.5
tfastfas_clarifier_sor_avgSecondary clarifier average SORm/h1.70.91.3
tfastfas_do_concentrationAeration tank DO concentrationmg/L212