Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Attached Growth Design: trickling filter

tf dosing rate 1p6 operating to tf effluent bod low rate

Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess type: trickling filter10 rowsPage 3 of 8
process typeparameter idparameter nameunitvalue maxvalue min
trickling filtertf dosing rate 1p6 operatingOperating dose at BOD loading 1.6 kg/m³·dmm/pass300100
trickling filtertf dosing rate 2p4 flushingFlushing dose at BOD loading 2.4 kg/m³·dmm/pass450
trickling filtertf dosing rate 2p4 operatingOperating dose at BOD loading 2.4 kg/m³·dmm/pass450150
trickling filtertf dosing rate 3p2 flushingFlushing dose at BOD loading 3.2 kg/m³·dmm/pass600
trickling filtertf dosing rate 3p2 operatingOperating dose at BOD loading 3.2 kg/m³·dmm/pass600200
trickling filtertf dosing rate low load flushingFlushing dose at low BOD loading (<0.4 kg/m³·d)mm/pass100
trickling filtertf dosing rate low load operatingOperating dose at low BOD loading (<0.4 kg/m³·d)mm/pass7525
trickling filtertf effluent bod high rate plasticEffluent BOD - high rate plasticmg/L30
trickling filtertf effluent bod high rate rockEffluent BOD - high rate rockmg/L30
trickling filtertf effluent bod low rateEffluent BOD - low ratemg/L30

What else is in Engineering Database