Attached Growth Design: mbbr
mbbr fullscale hrt lillehammer to mbbr removal flux nh4 nit max
Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.
| process type | parameter id | parameter name | unit | value min |
|---|---|---|---|---|
| mbbr | mbbr fullscale hrt lillehammer | Full-scale HRT - Lillehammer Norway (Bardenpho) | h | 3.2 |
| mbbr | mbbr fullscale hrt nordre follo | Full-scale HRT - Nordre Follo Norway (Bardenpho) | h | 4.9 |
| mbbr | mbbr fullscale hrt sjolunda | Full-scale HRT - Sjolunda Sweden (Post Anoxic) | h | 1.2 |
| mbbr | mbbr removal flux bod partial max | BOD removal flux - partial treatment maximum | g/m²·d | 20 |
| mbbr | mbbr removal flux bod partial min | BOD removal flux - partial treatment minimum | g/m²·d | 15 |
| mbbr | mbbr removal flux bod prenit max | BOD removal flux - prenitrification maximum | g/m²·d | 5 |
| mbbr | mbbr removal flux bod prenit min | BOD removal flux - prenitrification minimum | g/m²·d | 4 |
| mbbr | mbbr removal flux bod secondary max | BOD removal flux - secondary treatment maximum | g/m²·d | 15 |
| mbbr | mbbr removal flux bod secondary min | BOD removal flux - secondary treatment minimum | g/m²·d | 5 |
| mbbr | mbbr removal flux nh4 nit max | NH4-N removal flux - nitrification maximum | g/m²·d | 1.4 |