Property comparison of A 286 and ATI 601 (UNS N06601), both nickel alloy.

Nickel Alloy8 compared properties
PropertyA 286ATI 601 (UNS N06601)Difference
Yield strength655 MPa440 MPa-33%
Tensile strength1,000 MPa790 MPa-21%
Elongation24 %45 %+88%
Elastic modulus199,000 MPa205,000 MPa+3%
Density7,916 kg/m³8,050 kg/m³+2%
Thermal conductivity12.7 W/m·K11.2 W/m·K-12%
Specific heat461 J/kg·K460 J/kg·K0%
Coefficient of thermal expansion0.000017 1/K0.000014 1/K-17%

Difference is ATI 601 (UNS N06601) relative to A 286. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.

Identification

A 286
grade
S66286
standard
Special Metals / ATI Materials tech bulletin A-286 (UNS S66286); High Temp Metals A-286 tech data sheet
heat treatment
solution treat 982C/1h OQ + age 719C/16h AC
ATI 601 (UNS N06601)
grade
N06601
standard
ATI Technical Data Sheet
heat treatment
Annealed 982C (1800F)