Property comparison of A 286 and ATI 59 (UNS N06059), both nickel alloy.

Nickel Alloy6 compared properties
PropertyA 286ATI 59 (UNS N06059)Difference
Yield strength655 MPa310 MPa-53%
Tensile strength1,000 MPa690 MPa-31%
Elongation24 %45 %+88%
Elastic modulus199,000 MPa210,000 MPa+6%
Density7,916 kg/m³8,600 kg/m³+9%
Coefficient of thermal expansion0.000017 1/K0.000012 1/K-28%

Difference is ATI 59 (UNS N06059) relative to A 286. Values are taken from the representative row of each material; both materials may have multiple heat treatments or conditions on their individual pages.

Identification

A 286
grade
S66286
standard
Special Metals / ATI Materials tech bulletin A-286 (UNS S66286); High Temp Metals A-286 tech data sheet
heat treatment
solution treat 982C/1h OQ + age 719C/16h AC
ATI 59 (UNS N06059)
grade
N06059
standard
ATI Technical Data Sheet
heat treatment
Solution Annealed