Vibration Severity: ISO_10816_7_ROTODYNAMIC
Machinery vibration severity evaluation criteria — zone boundaries (A/B/C/D) for bearing housing velocity (mm/s RMS) and shaft displacement (micrometers pk-pk) per ISO 10816-1/3, ISO 20816-1/2/3, ISO 7919-3, API 610/617/611/612, NEMA MG1, VDI 3839, and ISO 14694. Covers ISO 10816-3 Groups 1 and 2 (rigid and flexible mount), ISO 10816-1 Classes I–IV, API centrifugal pump/compressor/steam turbine limits, rotodynamic pump zones, hydraulic machine zones, reciprocating machine limits, fan vibration limits, general alarm/trip multipliers, and summary lookup records.
| standard class | zone or limit | description | machine group | mounting | notes | unit | zone A max mm s (mm/s) | zone B max mm s (mm/s) | zone C max mm s (mm/s) | zone interpretation |
|---|---|---|---|---|---|---|---|---|---|---|
| ISO_10816_7_ROTODYNAMIC | ZONE_LIMITS | ISO 10816-7 rotodynamic pumps - bearing housing velocity zones | ISO_10816_7_Pump | any | ISO 10816-7:2009 covers rotodynamic pumps including centrifugal mixed-flow and axial; bearing housing velocity; applies at BEP and within POR | mm/s RMS | 2.3 | 4.5 | 7.1 | Zone A: <=2.3 mm/s; Zone B: 2.3-4.5 mm/s; Zone C: 4.5-7.1 mm/s; Zone D: >7.1 mm/s |