Vibration Severity: ALARM_TRIP_GENERAL

Machinery vibration severity evaluation criteria — zone boundaries (A/B/C/D) for bearing housing velocity (mm/s RMS) and shaft displacement (micrometers pk-pk) per ISO 10816-1/3, ISO 20816-1/2/3, ISO 7919-3, API 610/617/611/612, NEMA MG1, VDI 3839, and ISO 14694. Covers ISO 10816-3 Groups 1 and 2 (rigid and flexible mount), ISO 10816-1 Classes I–IV, API centrifugal pump/compressor/steam turbine limits, rotodynamic pump zones, hydraulic machine zones, reciprocating machine limits, fan vibration limits, general alarm/trip multipliers, and summary lookup records.

Mechanical Engineeringstandard_class: ALARM_TRIP_GENERAL2 rows
standard classzone or limitdescriptionmachine groupmountingnotesunitzone C max mm s (mm/s)zone interpretation
ALARM_TRIP_GENERALALERT_LEVELGeneral machinery alert (alarm) threshold multiplierGeneral_AlarmanyCommon practice per ISO 20816-1 Annex C and API 670; alert (alarm) set at 1.25x accepted baseline; trip at 2.0x baseline or applicable zone C/D boundary whichever is lowerx baseline1.25Alert set at 125% of initial baseline vibration level
ALARM_TRIP_GENERALTRIP_LEVELGeneral machinery danger (trip) threshold multiplierGeneral_TripanyTrip (shutdown) at 2.0x accepted baseline or zone D boundary; applies to non-API critical machines; API machines use API 670x baseline2Trip set at 200% of initial baseline vibration level