Home/Reference Data/Vibration Severity/ISO_10816_3_GRP1_RIGID

Vibration Severity: ISO_10816_3_GRP1_RIGID

Machinery vibration severity evaluation criteria — zone boundaries (A/B/C/D) for bearing housing velocity (mm/s RMS) and shaft displacement (micrometers pk-pk) per ISO 10816-1/3, ISO 20816-1/2/3, ISO 7919-3, API 610/617/611/612, NEMA MG1, VDI 3839, and ISO 14694. Covers ISO 10816-3 Groups 1 and 2 (rigid and flexible mount), ISO 10816-1 Classes I–IV, API centrifugal pump/compressor/steam turbine limits, rotodynamic pump zones, hydraulic machine zones, reciprocating machine limits, fan vibration limits, general alarm/trip multipliers, and summary lookup records.

Mechanical Engineeringstandard_class: ISO_10816_3_GRP1_RIGID3 rows
standard classzone or limitdescriptionmachine groupmountingnotespower kw min (kW)unitzone A max mm s (mm/s)zone B max mm s (mm/s)zone C max mm s (mm/s)zone interpretation
ISO_10816_3_GRP1_RIGIDA_B_BOUNDARYGroup 1 large rigid foundation - Zone A/B boundaryGroup_1_LargerigidGroup 1: rated power >300 kW or electrical machines shaft height H>=315 mm; rigid foundation (rigidly mounted on stiff foundation); ISO 10816-3:2009 Table 1300mm/s RMS2.32.32.3Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk
ISO_10816_3_GRP1_RIGIDB_C_BOUNDARYGroup 1 large rigid foundation - Zone B/C boundaryGroup_1_LargerigidGroup 1 rigid; Alert threshold at 4.5 mm/s300mm/s RMS2.34.54.5Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk
ISO_10816_3_GRP1_RIGIDC_D_BOUNDARYGroup 1 large rigid foundation - Zone C/D boundaryGroup_1_LargerigidGroup 1 rigid; Shutdown/trip threshold at 7.1 mm/s300mm/s RMS2.34.57.1Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk

This is a sample. Search the full vibration severity dataset and 300+ more by creating a free account and accessing the database.