Machinery vibration severity evaluation criteria — zone boundaries (A/B/C/D) for bearing housing velocity (mm/s RMS) and shaft displacement (micrometers pk-pk) per ISO 10816-1/3, ISO 20816-1/2/3, ISO 7919-3, API 610/617/611/612, NEMA MG1, VDI 3839, and ISO 14694. Covers ISO 10816-3 Groups 1 and 2 (rigid and flexible mount), ISO 10816-1 Classes I–IV, API centrifugal pump/compressor/steam turbine limits, rotodynamic pump zones, hydraulic machine zones, reciprocating machine limits, fan vibration limits, general alarm/trip multipliers, and summary lookup records.

Mechanical Engineeringstandard_class: ISO_10816_3_GRP1_FLEXIBLE3 rows
standard classzone or limitdescriptionmachine groupmountingnotespower kw min (kW)unitzone A max mm s (mm/s)zone B max mm s (mm/s)zone C max mm s (mm/s)zone interpretation
ISO_10816_3_GRP1_FLEXIBLEA_B_BOUNDARYGroup 1 large flexible foundation - Zone A/B boundaryGroup_1_LargeflexibleGroup 1 flexible (soft/flexible foundation); higher limits than rigid mount300mm/s RMS3.53.53.5Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk
ISO_10816_3_GRP1_FLEXIBLEB_C_BOUNDARYGroup 1 large flexible foundation - Zone B/C boundaryGroup_1_LargeflexibleGroup 1 flexible; Alert threshold 7.1 mm/s300mm/s RMS3.57.17.1Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk
ISO_10816_3_GRP1_FLEXIBLEC_D_BOUNDARYGroup 1 large flexible foundation - Zone C/D boundaryGroup_1_LargeflexibleGroup 1 flexible; Shutdown/trip threshold at 11.2 mm/s300mm/s RMS3.57.111.2Zone A: newly commissioned; Zone B: acceptable long-term; Zone C: plan corrective maintenance; Zone D: damage risk