Machinery vibration severity evaluation criteria — zone boundaries (A/B/C/D) for bearing housing velocity (mm/s RMS) and shaft displacement (micrometers pk-pk) per ISO 10816-1/3, ISO 20816-1/2/3, ISO 7919-3, API 610/617/611/612, NEMA MG1, VDI 3839, and ISO 14694. Covers ISO 10816-3 Groups 1 and 2 (rigid and flexible mount), ISO 10816-1 Classes I–IV, API centrifugal pump/compressor/steam turbine limits, rotodynamic pump zones, hydraulic machine zones, reciprocating machine limits, fan vibration limits, general alarm/trip multipliers, and summary lookup records.

Mechanical Engineeringstandard_class: ISO_10816_5_HYDRAULIC1 row
standard classzone or limitdescriptionmachine groupmountingnotesunitzone A max mm s (mm/s)zone B max mm s (mm/s)zone C max mm s (mm/s)zone interpretation
ISO_10816_5_HYDRAULICZONE_LIMITSISO 10816-5 hydraulic machines (pumps and turbines) velocity zonesISO_10816_5_HydraulicanyISO 10816-5:2000 covers hydraulic machines (water turbines pumps pump-turbines); lower limits than industrial rotating machinery due to high energy density and large massmm/s RMS1.62.54Zone A: <=1.6; Zone B: 1.6-2.5; Zone C: 2.5-4.0; Zone D: >4.0