Instrument Accuracy Specs: pressure_transmitter

Accuracy, range, and performance specifications for process measurement instruments. Covers pressure transmitters (standard, high-accuracy, economy), differential pressure transmitters, temperature transmitters (RTD, thermocouple), flow meters (magnetic, vortex, Coriolis, ultrasonic, turbine), level transmitters (radar, GWR, ultrasonic, DP), pH analyzers, conductivity analyzers, dissolved oxygen sensors (amperometric, optical), and turbidity meters. Each record includes accuracy (% span or % reading), repeatability, turndown ratio, response time, ambient/process temperature range, max pressure, output signal, SIL rating, and MTBF. 28 records from Emerson, E+H, Yokogawa, Siemens, and Hach instrument datasheets.

Electrical Engineeringinstrument_type: pressure_transmitter3 rows
instrument typemeasurement principleMTBF years (years)SIL ratingaccuracy pct of span (%)ambient temp range C max (degC)ambient temp range C min (degC)max pressure psi (psi)notesoutput signalprocess temp range C max (degC)process temp range C min (degC)range maxrange minrange unitrepeatability pct (%)response time s (s)
pressure_transmitterpiezoresistive/capacitive economy15SIL 20.07585-403,000Standard gauge pressure; 0.075% typical for economy class (Yokogawa EJA110E class)4-20mA HART200-401000psi0.011
pressure_transmitterpiezoresistive/capacitive high-accuracy17.8SIL 20.0485-406,000High-accuracy class (Rosemount 3051S or E+H PMC71); 0.04% reference accuracy; drift <0.1% URL/5yr4-20mA HART300-404,0000psi0.0051
pressure_transmitterpiezoresistive/capacitive standard17.8SIL 20.06585-403,626Rosemount 3051C class; includes multirange capability; accuracy is reference (20 deg C); total error band ~0.25% span4-20mA HART120-407500inH2O0.011