Instrument Accuracy Specs: flow_meter_turbine

Accuracy, range, and performance specifications for process measurement instruments. Covers pressure transmitters (standard, high-accuracy, economy), differential pressure transmitters, temperature transmitters (RTD, thermocouple), flow meters (magnetic, vortex, Coriolis, ultrasonic, turbine), level transmitters (radar, GWR, ultrasonic, DP), pH analyzers, conductivity analyzers, dissolved oxygen sensors (amperometric, optical), and turbidity meters. Each record includes accuracy (% span or % reading), repeatability, turndown ratio, response time, ambient/process temperature range, max pressure, output signal, SIL rating, and MTBF. 28 records from Emerson, E+H, Yokogawa, Siemens, and Hach instrument datasheets.

Electrical Engineeringinstrument_type: flow_meter_turbine1 row
instrument typemeasurement principleMTBF years (years)SIL ratingaccuracy pct of reading (%)ambient temp range C max (degC)ambient temp range C min (degC)max pressure psi (psi)notesoutput signalprocess temp range C max (degC)process temp range C min (degC)range maxrange minrange unitrepeatability pct (%)response time s (s)
flow_meter_turbinemechanical turbine (bearing)8SIL 10.565-203,000±0.5% rate at calibrated flow; sensitive to viscosity changes; bearing wear limits life; low-cost clean liquid service4-20mA pulse150-40500.1gpm0.11

This is a sample. Search the full instrument accuracy specs dataset and 300+ more by creating a free account and accessing the database.