Instrument Accuracy Specs: flow_meter_vortex

Accuracy, range, and performance specifications for process measurement instruments. Covers pressure transmitters (standard, high-accuracy, economy), differential pressure transmitters, temperature transmitters (RTD, thermocouple), flow meters (magnetic, vortex, Coriolis, ultrasonic, turbine), level transmitters (radar, GWR, ultrasonic, DP), pH analyzers, conductivity analyzers, dissolved oxygen sensors (amperometric, optical), and turbidity meters. Each record includes accuracy (% span or % reading), repeatability, turndown ratio, response time, ambient/process temperature range, max pressure, output signal, SIL rating, and MTBF. 28 records from Emerson, E+H, Yokogawa, Siemens, and Hach instrument datasheets.

Electrical Engineeringinstrument_type: flow_meter_vortex1 row
instrument typemeasurement principleMTBF years (years)SIL ratingambient temp range C max (degC)ambient temp range C min (degC)max pressure psi (psi)notesoutput signalprocess temp range C max (degC)process temp range C min (degC)range maxrange minrange unitrepeatability pct (%)response time s (s)
flow_meter_vortexvortex shedding liquid-gas13SIL 265-401,4800.75% rate typical liquid; 1.0% rate gas/steam; no moving parts; sensitive to vibration; min Reynolds 100004-20mA HART PROFIBUS400-200300.5ft/s (gas/liquid)0.52

This is a sample. Search the full instrument accuracy specs dataset and 300+ more by creating a free account and accessing the database.