Instrument Accuracy Specs: flow_meter_magnetic

Accuracy, range, and performance specifications for process measurement instruments. Covers pressure transmitters (standard, high-accuracy, economy), differential pressure transmitters, temperature transmitters (RTD, thermocouple), flow meters (magnetic, vortex, Coriolis, ultrasonic, turbine), level transmitters (radar, GWR, ultrasonic, DP), pH analyzers, conductivity analyzers, dissolved oxygen sensors (amperometric, optical), and turbidity meters. Each record includes accuracy (% span or % reading), repeatability, turndown ratio, response time, ambient/process temperature range, max pressure, output signal, SIL rating, and MTBF. 28 records from Emerson, E+H, Yokogawa, Siemens, and Hach instrument datasheets.

Electrical Engineeringinstrument_type: flow_meter_magnetic1 row
instrument typemeasurement principleMTBF years (years)SIL ratingaccuracy pct of span (%)ambient temp range C max (degC)ambient temp range C min (degC)max pressure psi (psi)notesoutput signalprocess temp range C max (degC)process temp range C min (degC)range maxrange minrange unitrepeatability pct (%)response time s (s)
flow_meter_magneticFaraday electromagnetic induction high-accuracy20SIL 20.260-20580High-accuracy class (E+H Promag 53/55 or Rosemount 8750W); 0.2% rate; approved for custody transfer; Schedule 1 liner options4-20mA HART PROFIBUS FOUNDATION Fieldbus200-10330.1ft/s0.12

This is a sample. Search the full instrument accuracy specs dataset and 300+ more by creating a free account and accessing the database.

Get started for FREE

Related data