Home/Reference Data/Hx Fouling Factors/tubular__organic_solvents__water to tubular__water__water

Hx Fouling Factors: tubular__organic_solvents__water to tubular__water__water

Heat exchanger fouling factors (fouling resistance) for various fluid services — single-fluid TEMA values plus combined (total dirt) fouling resistance for common shell-and-tube service pairs from Perry's CEH Table 11-3

Mechanical Engineeringservice_id: tubular__organic_solvents__water to tubular__water__water5 rows
service idfluid servicefouling factor combined hhf (h·ft2·°F/Btu)fouling factor max m2k w (m2K/W)fouling factor min m2k w (m2K/W)hx typeshell sidestandardtube side
tubular__organic_solvents__waterOrganic solvents / Water0.0030.0005280.000528shell-and-tubeOrganic solventsPerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Water
tubular__propane_butane__steam_vapPropane-butane / Steam condensing (vaporizer)0.00150.0002640.000264shell-and-tubePropane or butanePerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Steam condensing
tubular__steam__no6_fuel_oilSteam / No. 6 fuel oil0.00550.0009690.000969shell-and-tubeSteamPerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3No. 6 fuel oil
tubular__water__aromatic_vapor_azeotropeWater / Aromatic vapor-stream azeotrope0.0050.0008810.000881shell-and-tubeWaterPerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Aromatic vapor-stream azeotrope
tubular__water__waterWater / Water0.0030.0005280.000528shell-and-tubeWaterPerry's Chemical Engineers' Handbook, 8th Ed., Table 11-3Water