Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free

Attached Growth Design: baf

baf dnf loading continuous backwash min to baf o2 transfer df sunken 2p0m max

Attached growth biological treatment design parameters — trickling filter (low rate, high rate, partial BOD, nitrification), TFSC, TFAS, IFAS, MBBR carrier properties and removal/volumetric fluxes, and BAF volumetric loadings, oxygen transfer, denitrification loadings, and backwash rates. Source: Metcalf & Eddy Wastewater Engineering 5th Ed., Chapter 9.

Environmental Engineeringprocess type: baf10 rowsPage 3 of 5
process typeparameter idparameter nameunitvalue min
bafbaf dnf loading continuous backwash minDNF volumetric loading - continuous backwash minimumkg NO3-N/m³·d0.3
bafbaf dnf loading downflow sunken maxDNF volumetric loading - downflow sunken media maximumkg NO3-N/m³·d3.2
bafbaf dnf loading downflow sunken minDNF volumetric loading - downflow sunken media minimumkg NO3-N/m³·d0.3
bafbaf dnf loading upflow floating maxDNF volumetric loading - upflow floating media maximumkg NO3-N/m³·d2
bafbaf dnf loading upflow floating minDNF volumetric loading - upflow floating media minimumkg NO3-N/m³·d1.5
bafbaf dnf loading upflow sunken maxDNF volumetric loading - upflow sunken media maximumkg NO3-N/m³·d5
bafbaf dnf loading upflow sunken minDNF volumetric loading - upflow sunken media minimumkg NO3-N/m³·d0.8
bafbaf o2 transfer df sunken 1p6m maxBAF O2 transfer efficiency - downflow sunken 1.6 m depth maximum% per m depth5.5
bafbaf o2 transfer df sunken 1p6m minBAF O2 transfer efficiency - downflow sunken 1.6 m depth minimum% per m depth3.4
bafbaf o2 transfer df sunken 2p0m maxBAF O2 transfer efficiency - downflow sunken 2.0 m depth maximum% per m depth8.5

What else is in Engineering Database