| source type | BOD5 max mg L (mg/L) | BOD5 mg L (mg/L) | BOD5 min mg L (mg/L) | BOD COD ratio (dimensionless) | COD max mg L (mg/L) | COD mg L (mg/L) | COD min mg L (mg/L) | TKN max mg L (mg/L) | TKN mg L (mg/L) | TKN min mg L (mg/L) | TSS max mg L (mg/L) | TSS mg L (mg/L) | TSS min mg L (mg/L) | ammonia N max mg L (mg/L) | ammonia N mg L (mg/L) | ammonia N min mg L (mg/L) | conductivity uS cm (uS/cm) | description | pH max (pH) | pH min (pH) | pH typical (pH) | total phosphorus max mg L (mg/L) | total phosphorus mg L (mg/L) | total phosphorus min mg L (mg/L) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| landfill leachate young | 30,000 | 10,000 | 2,000 | 0.5 | 60,000 | 25,000 | 3,000 | 3,000 | 1,500 | 200 | 2,000 | 500 | 200 | 2,000 | 750 | 500 | 10,000 | Active or recent landfill, age < 2 years | 6.5 | 4.5 | 5.5 | 100 | 25 | 5 |
What else is in Engineering Database
Iron Engine ↗Engineering AI at ironengine.ai
AI built for engineering. Searches the engineering database, performs calculations, gives source-backed engineering insights.
Get started for free ↗Reference Data375 engineering tablesMaterial properties, pipe and shape dimensions, code tables, and electrical ratings across mechanical, civil, chemical, electrical, materials, and manufacturing engineering.
Browse dataCalculatorsDeterministic engineering calculatorsSizing, checking, and conversion tools that run against the reference tables. Inputs are code-compliant, outputs are traceable to the source standard.
Browse calculators