Sample data from Engineering Database — 375 reference tables, deterministic calculators, and Engineering AI. Sign up free
Home/Reference Data/Wastewater Characteristics/landfill leachate intermediate

Wastewater Characteristics: landfill leachate intermediate

Wastewater and leachate constituent concentrations — BOD5, COD, TSS, TKN, ammonia-N, total phosphorus, and pH typical values and ranges by source type (municipal, landfill leachate, stormwater, industrial)

Civil Engineeringsource type: landfill leachate intermediate1 row
source typeBOD5 max mg L (mg/L)BOD5 mg L (mg/L)BOD5 min mg L (mg/L)BOD COD ratio (dimensionless)COD max mg L (mg/L)COD mg L (mg/L)COD min mg L (mg/L)TKN max mg L (mg/L)TKN mg L (mg/L)TKN min mg L (mg/L)TSS max mg L (mg/L)TSS mg L (mg/L)TSS min mg L (mg/L)ammonia N max mg L (mg/L)ammonia N mg L (mg/L)ammonia N min mg L (mg/L)conductivity uS cm (uS/cm)descriptionpH max (pH)pH min (pH)pH typical (pH)total phosphorus max mg L (mg/L)total phosphorus mg L (mg/L)total phosphorus min mg L (mg/L)
landfill leachate intermediate4,0001,0002500.215,0005,0002,0002,5001,400500400100301,5001,00040010,000Transitional landfill, 2-10 years86.57.525102

What else is in Engineering Database

Calculators that use this data

Related data