module categoryoperating pointCOPImax A (A)Qmax W (W)Vmax V (V)ZTcooling capacity W (W)current A (A)delta T C (C)delta Tmax C (C)hot side temp C (C)input power W (W)materialmodule size mmvoltage V (V)
single stage standard50#201.07657.516.80.836520755033.8Bi2Te340x406.7
single stage standard50#300.67657.516.80.826.55.430755039.8Bi2Te340x407.4
single stage standard50#400.39657.516.80.8185.840755046.2Bi2Te340x408
single stage standard50#500.2657.516.80.810.5650755052Bi2Te340x408.6
single stage standard50#600.08657.516.80.84.5660755055.5Bi2Te340x409.2
single stage standard50#750657.516.80.80675755057.5Bi2Te340x409.6