module categoryoperating pointCOPImax A (A)Qmax W (W)Vmax V (V)ZTcooling capacity W (W)current A (A)delta T C (C)delta Tmax C (C)hot side temp C (C)input power W (W)materialmodule size mmnotesvoltage V (V)
single_stage_standard27#02.565316.40.8533.60682721.2Bi2Te340x40TEC1-12706 class module: 127 couples, 40x40x3.8mm, Qmax at dT=0. Optimized I=0.6*Imax for best COP at low dT. Th=300K.5.9
single_stage_standard27#101.6765316.40.842.54.210682725.5Bi2Te340x40dT=10K. Current increased toward optimum. Th=300K.6.1
single_stage_standard27#201.0665316.40.8324.820682730.2Bi2Te340x40dT=20K. Near-peak efficiency region for single-stage Bi2Te3. Th=300K.6.3